The Rheem 61-102321-10 is a factory-specified Thermostatic Expansion Valve (TXV) engineered for precise refrigerant metering in residential and light commercial HVAC systems. Designed for use with R-410A refrigerant, this valve delivers consistent, accurate flow control to maximize system efficiency and performance.

Key Specifications

  • Part Number: 61-102321-10
  • Refrigerant Type: R-410A
  • Capacity: 3 Ton
  • Inlet Connection: 1/2" ODF
  • Outlet Connection: 1/2" ODF
  • Capillary Length: 30 inches
  • Valve Type: Thermostatic Expansion Valve (TXV)

Features & Benefits

  • R-410A Compatible: Specifically rated for use with R-410A refrigerant, ensuring compatibility with modern, environmentally responsible HVAC systems.
  • 3-Ton Capacity: Sized to deliver optimal refrigerant flow for 3-ton system applications, maintaining proper superheat levels across varying load conditions.
  • Matched Inlet & Outlet Sizing: Both the 1/2" ODF inlet and 1/2" ODF outlet connections allow for straightforward installation and a consistent flow path through the valve body.
  • 30" Capillary Tube: The extended 30-inch capillary tube provides added flexibility during installation, allowing the sensing bulb to be properly positioned for accurate temperature sensing and responsive system control.
  • OEM Rheem Part: As a genuine Rheem component, this TXV is built to meet the exact specifications required for reliable, long-term operation in compatible Rheem systems.

Application & Compatibility

This TXV is intended for use in 3-ton R-410A HVAC systems where precise refrigerant metering is essential. The valve modulates refrigerant flow based on system demand, helping to maintain consistent superheat and protect the compressor from liquid slugging. Always verify compatibility with your specific Rheem system model before installation.

Installation Notes

The 1/2" ODF inlet and outlet connections are designed for brazing into the refrigerant circuit. Proper nitrogen purging and brazing procedures should be followed during installation. Secure the sensing bulb to the suction line using the included or appropriate hardware, and insulate as required to ensure accurate superheat readings.

Dimensions

Length: 1.0"
Width: 1.0"
Height: 1.0"

Part Rheem 61-102321-10 Expansion Valve/TXV, R-410A, 3 Ton, 1/2" Inlet, 1/2" Outlet, 30" Capillary fits 0 models

The Rheem 61-102321-10 is a factory-specified Thermostatic Expansion Valve (TXV) engineered for precise refrigerant metering in residential and light commercial HVAC systems. Designed for use with R-410A refrigerant, this valve delivers consistent, accurate flow control to maximize system efficiency and performance.

Key Specifications

  • Part Number: 61-102321-10
  • Refrigerant Type: R-410A
  • Capacity: 3 Ton
  • Inlet Connection: 1/2" ODF
  • Outlet Connection: 1/2" ODF
  • Capillary Length: 30 inches
  • Valve Type: Thermostatic Expansion Valve (TXV)

Features & Benefits

  • R-410A Compatible: Specifically rated for use with R-410A refrigerant, ensuring compatibility with modern, environmentally responsible HVAC systems.
  • 3-Ton Capacity: Sized to deliver optimal refrigerant flow for 3-ton system applications, maintaining proper superheat levels across varying load conditions.
  • Matched Inlet & Outlet Sizing: Both the 1/2" ODF inlet and 1/2" ODF outlet connections allow for straightforward installation and a consistent flow path through the valve body.
  • 30" Capillary Tube: The extended 30-inch capillary tube provides added flexibility during installation, allowing the sensing bulb to be properly positioned for accurate temperature sensing and responsive system control.
  • OEM Rheem Part: As a genuine Rheem component, this TXV is built to meet the exact specifications required for reliable, long-term operation in compatible Rheem systems.

Application & Compatibility

This TXV is intended for use in 3-ton R-410A HVAC systems where precise refrigerant metering is essential. The valve modulates refrigerant flow based on system demand, helping to maintain consistent superheat and protect the compressor from liquid slugging. Always verify compatibility with your specific Rheem system model before installation.

Installation Notes

The 1/2" ODF inlet and outlet connections are designed for brazing into the refrigerant circuit. Proper nitrogen purging and brazing procedures should be followed during installation. Secure the sensing bulb to the suction line using the included or appropriate hardware, and insulate as required to ensure accurate superheat readings.

Dimensions

Length: 1.0"
Width: 1.0"
Height: 1.0"

Part Rheem 61-102321-10 Expansion Valve/TXV, R-410A, 3 Ton, 1/2" Inlet, 1/2" Outlet, 30" Capillary fits 0 models

N/A
Rheem

Rheem 61-102321-10 Expansion Valve/TXV, R-410A, 3 Ton, 1/2" Inlet, 1/2" Outlet, 30" Capillary

$175.00

The Rheem 61-102321-10 is a factory-specified Thermostatic Expansion Valve (TXV) engineered for precise refrigerant metering in residential and light commercial HVAC systems. Designed for use with R-410A refrigerant, this valve delivers consistent, accurate flow control to maximize system efficiency and performance.

Key Specifications

Features & Benefits

Application & Compatibility

This TXV is intended for use in 3-ton R-410A HVAC systems where precise refrigerant metering is essential. The valve modulates refrigerant flow based on system demand, helping to maintain consistent superheat and protect the compressor from liquid slugging. Always verify compatibility with your specific Rheem system model before installation.

Installation Notes

The 1/2" ODF inlet and outlet connections are designed for brazing into the refrigerant circuit. Proper nitrogen purging and brazing procedures should be followed during installation. Secure the sensing bulb to the suction line using the included or appropriate hardware, and insulate as required to ensure accurate superheat readings.

Dimensions

Length: 1.0"
Width: 1.0"
Height: 1.0"
View product